Pyrolysis unit:
Specifications
|
Value
|
Pyrolysis unit capacity (Note 1)
|
from 50 up to 1000 kg/h (from 1 up to 25 TPD)
|
Feeding
|
continuous or intermittent (once every 10-12 hours)
|
AC mains voltage, V
|
3 phases, 380±10% (Note 2)
|
Supply voltage frequency, Hz
|
50/60
|
Power consumption of basic technological equipment, kW for every 2.5 tons per day
|
up to 20
|
Weight average temperature in pyrolysis reactor, °С
|
up to 650
|
Weight average temperature in combustion chamber, °С
|
up to 750
|
Fuel condensation system cooling
|
water, closed (Note 3)
|
Range of operating ambient temperature, °С
|
from - 60 up to + 50
|
Overall dimensions, L×W×H, m
|
correspond with the size of shipping containers (20/30/40 feet)
|
Number of containers
|
from 1 to 2 and more (Note 4)
|
Total unit weight, tonnes
|
from 8 to 40 (depending on the capacity)
|
Operation mode (duty cycle factor)
|
Continuous (Restarting=100%)
|
|
Fractionation unit:
Specifications
|
Value
|
Fractionation unit capacity (Note 1)
|
from 50 to 1000 litters per hour (from 1 to 25 tons per day)
|
Feeding
|
continuous or intermittent (once every 10-12 hours)
|
AC mains voltage, V
|
3 phases, 380-400 ±10% (Note 2)
|
Supply voltage frequency, Hz
|
50/60
|
Power consumption of basic technological equipment in kW for every 2 tons per day
|
up to 5
|
Operating temperature in fractionating column, °С
|
up to 380
|
Weight average temperature in fractionating reactor, °С
|
up to 560
|
Weight average temperature in combustion chamber, °С
|
up to 680
|
Fuel condensation system cooling
|
water, closed (Note 3)
|
Range of operating ambient temperature, °С
|
from - 60 to + 50
|
Overall dimensions, L×W×H, m
|
correspond with the size of shipping containers (20/30/40 feet)
|
Number of containers
|
from 1 to 2 and more (Note 4)
|
Total unit weight, tonnes
|
from 6 to 30 (depending on the capacity)
|
Operation mode (duty cycle factor)
|
continuous or non-stop (100% duty cycle in 2 shifts)
|
|
Plasma cracking unit:
Specifications
|
Value
|
Plasma cracking unit capacity (Note 1)
|
from 30 to 1000 kg per hour (from 0.5 to 25 tons per day)
|
Feeding
|
continuous / intermittent
|
AC mains voltage, V
|
3 phases, 380-400 ±10% (Note 2)
|
Supply voltage frequency, Hz
|
50/60
|
Power consumption of basic technological equipment, kW
|
corresponds to 10% of plasma system power
|
Plasma system power, kW
|
from 50 and more (depending on unit capacity)
|
Operating temperature in the contact area of plasma jet and processed material, °С
|
1000-1400
|
Fuel condensation system cooling
|
water, closed (Note 3)
|
Range of operating ambient temperature, °С
|
from - 60 to + 50
|
Overall dimensions, L×W×H, m
|
correspond with the size of shipping containers (20/30/40 feet)
|
Number of containers
|
from 1 to 2 and more (Note 4)
|
Total unit weight, tonnes
|
from 3,5 to 30 (depending on the capacity)
|
Operation mode (duty cycle factor)
|
Continuous (Restarting=100%)
|
|
Fuel storage unit:
Specifications
|
Value
|
Volume of fuel for storage and exchange between pyrolysis, distillation and plasma cracking units (Note 1)
|
corresponds to double capacity of pyrolysis, fractionation and plasma cracking unit
|
Types of stored fuel
|
liquid synthetic fuel, heavy hydrocarbon fraction, gasoline and diesel fractions
|
AC mains voltage, V
|
3 phases, 380-400 ±10% (Note 2)
|
Supply voltage frequency, Hz
|
50/60
|
Power consumption of basic technological equipment, kW
|
2
|
Range of operating ambient temperature, °С
|
from - 60 to + 50
|
Overall dimensions, L×W×H, m
|
correspond with the size of shipping containers (20/30/40 feet)
|
Number of containers
|
from 1 to 2 and more (Note 4)
|
Total unit weight, tonnes
|
from 1 to 40 (depending on the capacity)
|
Operation mode (duty cycle factor)
|
continuous, non-stop (100% duty cycle)
|
|
Notes:
1 - Production of units on order for plasma pyrolysis with capacity up to 80 tons per day (HGP-3000) and up to 100 tons per day (HGP-5000) is possible.
2 - Power source provides automatic adjustment to any input voltage in the range of 380-450 V for three phases.
3 - Selection of cooling depends on the terms of reference for the development of plasma pyrolysis unit.
4 - The unit is based on standard 20/30/40 feet-containers; the number of containers from 1 to 6 or more (depends on the desired parameters of disposal, number, and capacity of basic units, type of waste, and customer's request).
5 - All parameters of plasma pyrolysis unit are manufactured according to customer's request. |